Products

H13–U16 PTFE Mini-Pleat HEPA/ULPA Filter for Cleanrooms

H13–U16 PTFE Mini-Pleat HEPA/ULPA Filter for Cleanrooms

Features

Low-resistance PTFE membrane filtration in 30 mm and 50 mm panel depths for cleanroom terminals, FFUs and controlled industrial air systems. Standard grades include H13, H14, U15 and U16. The HF-PTFE filter uses PTFE membrane media in a compact pleated panel. It is designed for projects that require high particulate filtration efficiency with controlled initial resistance. Standard aluminum-alloy panels are available in three face sizes and two depths, with rated airflow from 470 to 2100 m³/h.
  • H13 to U16 Grade Options:Select the required grade against the project test standard and cleanliness target.
  • Low Initial Resistance:Published initial resistance ranges from 65 to 115 Pa, depending on panel depth and efficiency grade, at the stated rated airflow.
  • Compact Panel Depth:Standard 30 mm and 50 mm options support installations where filter depth is limited.
  • Project-Specific Configuration:Dimensions, airflow, seal, labeling and packaging can be reviewed for OEM and cleanroom projects.

Fast Sampling Support

Samples ready within 3–7 days for custom OEM & ODM orders. Flexible customization solutions are available to match your unique product requirements.

Advanced Production Equipment & Stable Quality

Equipped with professional automated production lines and sophisticated testing machinery, enabling consistent, reliable product quality across all batches.

Mass Production & On-Time Shipment

Efficient full-scale manufacturing capacity ensures finished goods can be delivered within 15–20 working days, guaranteeing punctual shipment schedules.

ISO Standard Strict Quality Control

All production follows strict ISO 9001 standards. Each shipment carries a complete quality inspection certificate to satisfy factory release specifications.

Request a Technical Review

Send the required efficiency grade, test standard, W × H × D, rated airflow, allowable initial resistance, sealing method and quantity. State whether an individual scan-test report or other release document is required.

  • Chat With an Engineer
  • Request a Quote
  • Email Your Filter Schedule or Drawing

Why Use PTFE Membrane Media?

PTFE membrane media can provide high particle-capture efficiency at a lower resistance than a conventional glass-fiber configuration designed for the same duty. The actual difference must be compared at the same filter size, grade, airflow and test method.

The membrane construction is also selected where resistance to moisture or specific process chemicals is important. Compatibility is not universal. Provide the chemical name, concentration, temperature, humidity and exposure pattern before specifying the filter for a corrosive or decontamination environment.

Compact Mini-Pleat Construction

The pleated pack increases the effective media area within a 30 mm or 50 mm panel. A deeper 50 mm filter provides lower published initial resistance than the corresponding 30 mm model at the same face size, airflow and efficiency grade.

The final configuration includes the PTFE media pack, aluminum-alloy frame and selected sealing components. Gasket, gel or other sealing arrangements must match the terminal housing and installation method.

Efficiency and Testing

The current product range lists H13, H14, U15 and U16. Before ordering, confirm:

  • the applicable EN 1822 or ISO 29463 edition;
  • the required overall and local efficiency at MPPS;
  • the rated airflow used for the test;
  • the challenge aerosol and scan method;
  • the leakage acceptance limit;
  • whether the buyer needs an individual report, label values or lot-level certificate.

The existing page states that filters are individually tested and that airflow, resistance, efficiency and leakage are inspected before shipment. The exact test procedure and document format must be confirmed in the quotation.

Applications

  • Cleanroom Terminal Filtration:Final-stage filtration for controlled supply-air systems.
  • Fan Filter Units:Thin panel options for FFU configurations that match the listed dimensions and airflow.
  • Semiconductor and Electronics Production:Particle control in clean manufacturing areas, subject to process-specific contamination and material requirements.
  • Pharmaceutical and Biotech Facilities:Clean-air filtration where the selected grade, sealing and test documentation meet the project specification.
  • Laboratories:Supply-air or equipment filtration for controlled environments.
  • Industrial HVAC Terminals:Final filtration where high efficiency and low initial resistance are required.

Hospital, food-processing and other regulated applications require project-specific review. A filtration grade alone does not establish regulatory compliance.

Technical Parameters

Model Dimensions W × H × D (mm) Rated Airflow (m³/h) H13 Initial Resistance (Pa) H14 Initial Resistance (Pa) U15 Initial Resistance (Pa) U16 Initial Resistance (Pa)
HF-PTFE 570 × 570 × 30 470 75 80 95 115
HF-PTFE 1170 × 570 × 30 1000 75 80 95 115
HF-PTFE 1170 × 1170 × 30 2100 75 80 95 115
HF-PTFE 570 × 570 × 50 470 65 70 85 100
HF-PTFE 1170 × 570 × 50 1000 65 70 85 100
HF-PTFE 1170 × 1170 × 50 2100 65 70 85 100

 

*Initial resistance values apply at the stated rated airflow. Confirm the test standard, tolerance and final approved specification before ordering.*

Standard Model Options

Model Size (mm) Rated Airflow (m³/h) Available Grades Initial Resistance Range
HF-PTFE-57030 570 × 570 × 30 470 H13 / H14 / U15 / U16 75–115 Pa
HF-PTFE-117030 1170 × 570 × 30 1000 H13 / H14 / U15 / U16 75–115 Pa
HF-PTFE-11711730 1170 × 1170 × 30 2100 H13 / H14 / U15 / U16 75–115 Pa
HF-PTFE-57050 570 × 570 × 50 470 H13 / H14 / U15 / U16 65–100 Pa
HF-PTFE-117050 1170 × 570 × 50 1000 H13 / H14 / U15 / U16 65–100 Pa
HF-PTFE-11711750 1170 × 1170 × 50 2100 H13 / H14 / U15 / U16 65–100 Pa

 

Construction and Ordering Specification

Item Confirmed or Required Information
Product Type PTFE membrane mini-pleat HEPA/ULPA panel filter
Model Series HF-PTFE
Efficiency Grades H13 / H14 / U15 / U16
Filter Media PTFE filter paper / membrane media
Frame Aluminum alloy
Standard Depth 30 mm / 50 mm
Standard Face Sizes 570 × 570 / 1170 × 570 / 1170 × 1170 mm
Rated Airflow 470 / 1000 / 2100 m³/h according to size
Separator [TO CONFIRM]
Sealant [TO CONFIRM]
Gasket or Gel Seal Custom option stated; exact materials [TO CONFIRM]
Faceguard [TO CONFIRM]
Maximum Temperature [TO CONFIRM: °C]
Maximum Relative Humidity [TO CONFIRM: % RH and condensation condition]
Recommended Final Pressure Drop [TO CONFIRM: Pa]
Efficiency Standard [TO CONFIRM: EN 1822 / ISO 29463 edition]
Individual Test Stated as performed; method and report [TO CONFIRM]
Label Data [TO CONFIRM]
Packaging Custom packaging stated; standard method [TO CONFIRM]

 

Customization and Quality Control

Dimensions and Airflow

Custom sizes and airflow ratings can be reviewed against the terminal or FFU drawing. Pressure drop must be confirmed at the requested rated airflow.

Efficiency Grade

H13, H14, U15 and U16 are listed as available. Do not select a grade by efficiency percentage alone; specify the standard, test method and local leakage requirement.

Sealing

The page lists custom gasket and sealing options. Provide the housing drawing, sealing direction and contact surface so the filter-to-housing interface can be checked.

Inspection

The current quality-control scope includes material inspection, pleating and assembly control, airflow, resistance, efficiency, leakage and appearance inspection. Confirm which results appear on the label, inspection certificate or individual report.

Product Detail Image Plan

Image 1: PTFE Mini-Pleat Structure

Suggested labels: PTFE Membrane Media, Mini-Pleat Pack, Separator, Aluminum-Alloy Frame, Sealant, Gasket/Gel Option.

Only label separator, sealant and seal materials after the construction is confirmed.

Image 2: 30 mm vs 50 mm Depth

Show the same face size and grade at the published airflow, then state the corresponding initial resistance. This provides a useful engineering comparison without an unsupported energy-savings percentage.

Image 3: Test and Identification

Show the actual efficiency/leak test station, pressure-drop measurement, serial label and report format. Add the test standard only if it is visible in the real document.

Image 4: Installation and Packaging

Show FFU or terminal installation direction, seal interface, individual bag protection, corner protection and carton/wooden-case packaging as actually supplied.

FAQ

What efficiency grades are available?

The current range lists H13, H14, U15 and U16. Confirm the required EN 1822 or ISO 29463 classification and MPPS acceptance criteria before ordering.

Is the PTFE HEPA filter washable?

The current technical content does not provide an approved washing procedure or post-wash performance data. The filter should not be marketed or maintained as washable unless Healthy Filters supplies a validated cleaning method.

Is this a high-temperature HEPA filter?

No maximum operating temperature is stated on the page. Do not select it for a high-temperature process until the PTFE media, adhesive, frame and sealing components have been reviewed against the required temperature.

Why does the 50 mm filter have a lower initial resistance?

The published table shows lower initial resistance for the 50 mm version than the 30 mm version at the same face size, airflow and grade. The deeper pack provides more room for filter media within the panel.

Is every filter individually tested?

The current page states that individual performance testing is performed before shipment. Confirm the test method, leakage limit and report format in the quotation, especially for cleanroom validation projects.

What information is required for a quotation?

Provide W × H × D, efficiency grade, test standard, rated airflow, maximum initial resistance, housing/seal type, operating temperature and humidity, quantity, label requirements and required test documents.

PRODUCT DETAILS

PTFE HEPA Filter PTFE HEPA Filter

 

RELATED PRODUCT
High Temperature HEPA Filter H13 H14
Replaceable Integrated Air Filter for Home Office Use High-Efficiency Easy to Install Long-Lasting04
Glassfiber Media High Temperature HEPA Filter with Frame and Aluminum Separators01
OEM H14 High Air Filters Glass Fiber High Temperature HEPA Industrial Filter-1

GET A FREE QUOTE