✔ Mini-pleat design for maximum filtration area
✔ High airflow capacity with low pressure drop
✔ Filtration efficiency up to U15 grade
✔ Advanced hot-melt separator technology
✔ High dust holding capacity
✔ Compact and lightweight structure
✔ Energy-saving operation
✔ Uniform airflow distribution
✔ Long service life and reduced maintenance costs
✔ Custom sizes and specifications available
✔ Individually tested before delivery
The Mini-Pleat HEPA Filter is engineered to meet the demanding air cleanliness requirements of modern cleanrooms and industrial facilities. Compared with traditional separator-type filters, the mini-pleat design allows more filter media to be packed into a compact frame, resulting in higher airflow, lower resistance, and longer service life.
Manufactured with premium fiberglass paper and advanced hot-melt separator technology, the filter ensures uniform airflow distribution while maximizing dust-holding capacity. The lightweight construction and reduced energy consumption make it an ideal choice for high-performance HVAC and cleanroom filtration systems.
Available in multiple efficiency grades from H10 to U15, these filters are individually tested to ensure reliable performance and compliance with stringent air quality standards.
| Model | Dimensions (mm) | Rated Airflow (m³/h) | H10 Initial Resistance (Pa) | H11 (Pa) | H13 (Pa) | H14 (Pa) | U15 (Pa) |
|---|---|---|---|---|---|---|---|
| HF-HV | 610 × 305 × 69 | 300 | 75 | 85 | 115 | 120 | 145 |
| HF-HV | 610 × 610 × 69 | 550 | 75 | 85 | 115 | 120 | 145 |
| HF-HV | 570 × 570 × 69 | 500 | 75 | 85 | 115 | 120 | 145 |
| HF-HV | 1170 × 570 × 69 | 1000 | 75 | 85 | 115 | 120 | 145 |
| HF-HV | 1170 × 1170 × 69 | 2000 | 75 | 85 | 115 | 120 | 145 |
| HF-HV | 610 × 305 × 90 | 300 | 70 | 80 | 110 | 115 | 140 |
| HF-HV | 610 × 610 × 90 | 550 | 70 | 80 | 110 | 115 | 140 |
| HF-HV | 570 × 570 × 90 | 500 | 70 | 80 | 110 | 115 | 140 |
| HF-HV | 1170 × 570 × 90 | 1000 | 70 | 80 | 110 | 115 | 140 |
| HF-HV | 1170 × 1170 × 90 | 2000 | 70 | 80 | 110 | 115 | 140 |
| HF-HV | 610 × 305 × 120 | 300 | 65 | 75 | 105 | 110 | 135 |
| HF-HV | 610 × 610 × 120 | 550 | 65 | 75 | 105 | 110 | 135 |
| HF-HV | 570 × 570 × 120 | 500 | 65 | 75 | 105 | 110 | 135 |
| HF-HV | 1170 × 570 × 120 | 1000 | 65 | 75 | 105 | 110 | 135 |
| HF-HV | 1170 × 1170 × 120 | 2000 | 65 | 75 | 105 | 110 | 135 |
| HF-HV | 610 × 610 × 150 | 550 | 60 | 70 | 100 | 105 | 130 |
| HF-HV | 1170 × 570 × 150 | 1000 | 60 | 70 | 100 | 105 | 130 |
| HF-HV | 610 × 610 × 220 | 550 | 55 | 65 | 110 | 100 | 125 |
| HF-HV | 1170 × 570 × 220 | 1000 | 55 | 65 | 110 | 100 | 125 |
| HF-HV | 610 × 610 × 95 | 550 | 50 | 60 | 110 | 90 | 120 |
| HF-HV | 1170 × 570 × 95 | 1000 | 50 | 60 | 110 | 90 | 120 |
| Model | Size (mm) | Rated Airflow (m³/h) | Efficiency Grade | Initial Resistance Range |
|---|---|---|---|---|
| HF-HV-61030569 | 610 × 305 × 69 | 300 | H10 / H11 / H13 / H14 / U15 | 75–145 Pa |
| HF-HV-61061069 | 610 × 610 × 69 | 550 | H10 / H11 / H13 / H14 / U15 | 75–145 Pa |
| HF-HV-57057069 | 570 × 570 × 69 | 500 | H10 / H11 / H13 / H14 / U15 | 75–145 Pa |
| HF-HV-117057069 | 1170 × 570 × 69 | 1000 | H10 / H11 / H13 / H14 / U15 | 75–145 Pa |
| HF-HV-1170117069 | 1170 × 1170 × 69 | 2000 | H10 / H11 / H13 / H14 / U15 | 75–145 Pa |
| HF-HV-61061090 | 610 × 610 × 90 | 550 | H10 / H11 / H13 / H14 / U15 | 70–140 Pa |
| HF-HV-117057090 | 1170 × 570 × 90 | 1000 | H10 / H11 / H13 / H14 / U15 | 70–140 Pa |
| HF-HV-610610120 | 610 × 610 × 120 | 550 | H10 / H11 / H13 / H14 / U15 | 65–135 Pa |
| HF-HV-1170570120 | 1170 × 570 × 120 | 1000 | H10 / H11 / H13 / H14 / U15 | 65–135 Pa |
| HF-HV-610610150 | 610 × 610 × 150 | 550 | H10 / H11 / H13 / H14 / U15 | 60–130 Pa |
| Application Area | Typical Use |
|---|---|
| Cleanrooms | Terminal filtration for high-cleanliness environments |
| Electronics Manufacturing | Particle control in precision production areas |
| Semiconductor Facilities | Final filtration for clean production lines |
| Precision Machinery | Protection of sensitive equipment and processes |
| Pharmaceutical Industry | Clean air supply for production and packaging areas |
| Hospitals | Air purification for operating rooms and clean medical spaces |
| Food Processing | High-cleanliness air filtration in processing areas |
| Laboratories | Particle control in controlled testing environments |
| Biotechnology Facilities | Clean air supply for sensitive production areas |
| HVAC Terminal Systems | Final-stage filtration in clean air-conditioning systems |
| Category | Customization Options / Quality Assurance |
|---|---|
| Custom Dimensions | Customized sizes available for different cleanroom and HVAC terminal systems. |
| Efficiency Grade | H10, H11, H13, H14, and U15 options available. |
| Filter Thickness | 69 mm, 90 mm, 120 mm, 150 mm, 220 mm, and other specifications available upon request. |
| Filter Media | Fiberglass filter paper selected according to filtration efficiency requirements. |
| Frame Material | Aluminum alloy, galvanized steel, or stainless steel frame options available. |
| Protective Mesh | Plastic-coated mesh protection available on inlet and outlet sides. |
| Sealing Method | Polyurethane sealant ensures reliable sealing performance. |
| Airflow Capacity | Customized airflow ratings available for project-specific requirements. |
| OEM & Branding | OEM manufacturing, private labeling, and customized packaging supported. |
| Material Inspection | Filter media, sealant, and frame materials are checked before production. |
| Production Control | Mini-pleat spacing, frame assembly, and sealing process are strictly controlled. |
| Performance Testing | Airflow, resistance, efficiency, leakage, and appearance inspection before shipment. |
| Final Inspection | Each filter is inspected before packaging and delivery. |
Product Details
![]() |
![]() |